Fakta om udbudet
Udbyder
University of Copenhagen
Acquisition of a ABPMpro – ambulatory blood pressure monitor
University of Copenhagen
Voluntary ex ante transparency notice
Supplies
Section I: Contracting authority/entity
Postal address: Nørregade 10
Town: Copenhagen K
NUTS code: DK01 Hovedstaden
Postal code: 1165
Country: Denmark
Contact person: Mahmut Yüksel
E-mail: fgn253@ku.dk
Internet address(es):
Main address: www.KU.dk
Section II: Object
Acquisition of a ABPMpro – ambulatory blood pressure monitor
Novo Nordisk Foundation Center for Basic Metabolic Research (CBMR) was established in 2010 at the Faculty of Health and Medical Sciences, University of Copenhagen.
The vision is to strengthen interdisciplinary research that transforms the basic understanding of the mechanisms involved in metabolic health and disease and to accelerate this knowledge toward new prevention and treatment strategies.
The purchase of ABPMpro devices (SOMNOmedics) is an essential part of the data collection for the Danish Precision Health Initiative, where we collect data on multiple aspects of the cardiometabolic health status of participants. This research project leverage from other cohorts by including “at-home” data collection using Vanguard technologies, where the ABPMpro is one of these technologies. The ABPMpro is a unique patented technology for the measurement of 24h ambulatory blood pressure monitoring (and other essential blood pressure components) without any tubes or wires disturbing the everyday life of particpants.
Section IV: Procedure
- The works, supplies or services can be provided only by a particular economic operator for the following reason:
- absence of competition for technical reasons
The ABPMpro device is the only technology available on the market, which is capable of combining the following product characteristics in a single device simultaneously:
- Blood pressure measurement via oscillometry
- Continuous blood pressure measurement via pulse-transit-time method.
- ABPM device attached directly to the upper-arm cuff (no tubing required)
- Cuff integrated 1-channel ECG for the detection of heart rate variability.
- 3-channel ECG recording
- Optical sensor for PPG, which can be used to display the pulse wave and for the detection of sleep arousals
- Intelligent inflation and/or deflation measurement of cuff blood pressure
- Activity and body position sensor (arm).
- Body position sensor (thorax)
- Impedance Cardiography via 3-channel-ECG sensor for the detection of breathing.
Section V: Award of contract/concession
Postal address: Stephanstrasse 19
Town: Aachen
NUTS code: DE Deutschland
Postal code: 52064
Country: Germany
Section VI: Complementary information
Postal address: Nævnenes hus, tolboden 2
Town: Viborg
Postal code: 8800
Country: Denmark
E-mail: NH@naevneneshus.dk
Telephone: +45 72405600
Internet address: www.KLFU.dk